DATA TRANSMISSON REQUIRMENTS DATA TRANSMISSON-SERIAL SYSTEM (PORT)  RS232 PLC (PORT)     DF PORT BAUD RATE -9.6KBPS TO 19.2 KBPS ...


DATA TRANSMISSON REQUIRMENTS

  1. DATA TRANSMISSON-SERIAL
  2. SYSTEM (PORT)  RS232
  3. PLC (PORT)     DF PORT
  4. BAUD RATE -9.6KBPS TO 19.2 KBPS
  5. PROFRAMMING SOFTWARE -S7 200


Throughout this course we will be using the S7-200 PLC for specific examples of PLC concepts. The S7-200 PLC is used for this purpose because of its ease of use and wide-spread application.
The items shown in the following illustration are needed to create or change an S7-200 PLC program. The program is created using STEP 7-Micro/WIN programming software, which runs on a Windows-based personal computer (Win2000,
Windows XP, and higher operating system). A special cable is needed when a personal computer is used as a programming device. Two versions of this cable are available. One version, called an RS-232/PPI Multi-Master Cable, connects a personal computer’s RS-232 interface to the PLC’s RS-485 connector. The other version, called a USB/PPI Multi- Master Cable, connects a personal computer’s USB interface to the PLC’s RS-485 connector.
Profibus/MPI
           
Profibus
PROFIBUS in the SIMATIC open, multivendor communication system represents
the network at the cell and field level.
PROFIBUS is available in two versions:

  1. PROFIBUS DP field bus for fast cyclic data exchange, and PROFIBUS-PA for
the intrinsically safe area.

  1. The cel level as PROFIBUS (FDL or PROFIBUS-FMS) for fast data exchange
with communication partners equipped with equal rights.
However, you can also implement PROFIBUS DP and PROFIBUS-FMS with
communication processors (CP).

MPI
MPI is a small subnet with just a few nodes at the field/cell level. It is a multi point capable
interface in SIMATIC S7/M7 and C7, intended for operation as PG
interface for networking just a few CPUs or for exchanging small volumes of data
with PGs.

MPI always retains the last configuration of the transmission rate, node number
and highest MPI address, even after memory reset, voltage failure or deletion of
the CPU parameter configuration.

These maximum transmission rates are possible:

MPI
                 12 Mbps with CPU 318-2 DP
                  187.5 Kbps with all other CPUs

 PROFIBUS DP    12 Mbps

COMMENTS

/fa-fire/ YEAR POPULAR$type=one

Name

AUTOMATION,2,PLC,10,SCADA,1,
ltr
item
Automation | PLC | SCADA | HMI | DRIVES | PNEMATICS: DATA TRANSMISSON REQUIRMENTS ???
DATA TRANSMISSON REQUIRMENTS ???
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgG00fbhOvGyvIfpyb0ZqYmaDNBKFO2cHo2Tg6uHQQlmzuXP78gqwUi27zWx1ElA2oxosiQi-tM-DDhzpdkS71zpEXXXHJuepbxX-caHGM90w4-pVv3K_1VyqjuXGhARLcIPVOoOG-gkDVt/s320/rs+332.png
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgG00fbhOvGyvIfpyb0ZqYmaDNBKFO2cHo2Tg6uHQQlmzuXP78gqwUi27zWx1ElA2oxosiQi-tM-DDhzpdkS71zpEXXXHJuepbxX-caHGM90w4-pVv3K_1VyqjuXGhARLcIPVOoOG-gkDVt/s72-c/rs+332.png
Automation | PLC | SCADA | HMI | DRIVES | PNEMATICS
https://nowautomation.blogspot.com/2016/05/data-transmisson-requirments.html
https://nowautomation.blogspot.com/
https://nowautomation.blogspot.com/
https://nowautomation.blogspot.com/2016/05/data-transmisson-requirments.html
true
2166312147522626366
UTF-8
Loaded All Posts Not found any posts VIEW ALL Readmore Reply Cancel reply Delete By Home PAGES POSTS View All RECOMMENDED FOR YOU LABEL ARCHIVE SEARCH ALL POSTS Not found any post match with your request Back Home Sunday Monday Tuesday Wednesday Thursday Friday Saturday Sun Mon Tue Wed Thu Fri Sat January February March April May June July August September October November December Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec just now 1 minute ago $$1$$ minutes ago 1 hour ago $$1$$ hours ago Yesterday $$1$$ days ago $$1$$ weeks ago more than 5 weeks ago Followers Follow THIS PREMIUM CONTENT IS LOCKED STEP 1: Share to a social network STEP 2: Click the link on your social network Copy All Code Select All Code All codes were copied to your clipboard Can not copy the codes / texts, please press [CTRL]+[C] (or CMD+C with Mac) to copy Table of Content